- Rigg & sail
- Rope & cordage
- Anchoring & mooring
- Hull & deck
- Cabin & comfort
- Paint & boatbuilding
-
Electrics & engine
- Batteries & accessories
- Onboard monitoring
- Onboard power systems
- Cables & accessories
- Network & NMEA2000
- Battery chargers
- Inverters & voltage converters
- Wind chargers, solar panels & fuel cells
- Electric engines
- Engine control & push pull cables
- Engine cooling & exhaust system
- Accessories for engines
- Fuel system
- Pumps & sanitation
- Safety & VHF radio
- Navigation & books
- Commercial shipping
VETUS Airvent ASD38 Aerator
Belüfter zur Verhinderung des Saugheber-Effekts in Kühlwasser- und Abwasserleitungen. Zum Einbau in der Auslassleitung.
Notwendig für alle Installationen unterhalb der Wasserlinie.
Lieferbar als
- ASD38V mit federbelastetem Ventil.
- ASD38H mit Außenbord-Luftschlauch Länge 4,0 m (inklusive Borddurchlass)
Für Schlauchdurchmesser 38 mm.
from €119.00*
€119.00
Prices incl. VAT plus shipping costs
| Art. No. | B (mm) | H (mm) | T (mm) | model | valve | Unit price | Delivery time | Note list | Buy |
|---|
Description
Belüfter zur Verhinderung des Saugheber-Effekts in Kühlwasser- und Abwasserleitungen. Zum Einbau in der Auslassleitung.
Notwendig für alle Installationen unterhalb der Wasserlinie.
Lieferbar als
- ASD38V mit federbelastetem Ventil.
- ASD38H mit Außenbord-Luftschlauch Länge 4,0 m (inklusive Borddurchlass)
Für Schlauchdurchmesser 38 mm.
Downloads
Anti syphon for motor cooling water outlet or for toilet outlet. Can be connected to hoses with internal diameters of 13, 19, 25 and 32 mm. AIRVENT H without valve, comes with 4,0 m plastic hose diameter 8 mm. AIRVENT V with spring loaded valve.
Very flexible exhaust hose for water-cooled (wet) exhaust systems on board yachts. It has R.I.N.A. (DIP 075110CS) and Lloyds (No. 96/00127) approval for diesel and also petrol engines with very high exhaust temperatures. Approved from -30 to +100° Celsius, short-term loads also up to 115° Celsius. The hose is available in various inner diameters from 40 to 90 millimeters.This hose has a very small bending radius due to the integrated steel spiral, the values for which can be found in the table. It also complies with the US standard SAE J 2006:2003 R1/R2 and the ISO standard 13363:2006 Tipo 2 Classe BAvailable to measure in whole 1-meter increments. Customized goods cannot be returned.
Connectors specially made for water cooled exhaust pipes made from PVC.Also well suited to connect already existing and sound hoses with new exhaust components.Available straight and 60° angular.
Original Vetus exhaust hose in very flexible exhaust hose with Lloyds approval.The special type of rubber and the tightly wound inner spiral enable installation even in confined spaces. The possible bending radius is one and a half times the diameter.Temperature-resistant from -30° C to +100° C with a short-term peak load of +115° C.Only sections in whole 1 meter increments are available. Customized goods cannot be returned.Other hose diameters on request.
Very thick-walled and heavy through-hull made from seawater-proof marine bronze (CuSn5Zn5Pb5).Attached to the hull using countersunk fastener holes, drilled through the strong flange.Molded from bronze in a single piece, tumbled matte finish.Intended for exhaust and cooling water.
Anti syphon for motor cooling water outlet or for toilet outlet. Can be connected to hoses with internal diameters of 13, 19, 25 and 32 mm. AIRVENT H without valve, comes with 4,0 m plastic hose diameter 8 mm. AIRVENT V with spring loaded valve.
Belüfter zur Verhinderung des Saugheber-Effekts in Kühlwasser- und Abwasserleitungen. Zum Einbau in der Auslassleitung.Notwendig für alle Installationen unterhalb der Wasserlinie.Lieferbar als- ASD38V mit federbelastetem Ventil.- ASD38H mit Außenbord-Luftschlauch Länge 4,0 m (inklusive Borddurchlass)Für Schlauchdurchmesser 38 mm.
Exhaust connection in EDPM rubber with high gloss polished stainless steel trim ring (AISI 316) Type TRCR. Mounting on the counter or the tailboard. The flanges are fitted from the outside and do not need a lock bush from the inside. For connection of the exhaust hose, a hose connector will be required.
Transom exhaust connection, with integrated check valve TYP TRCSV. High quality stainless steel AISI 316 with high gloss polished cover to conceal fixings. The flanges are fitted from the outside and do not need a lock bush from the inside. The exhaust hose can be fitted directly to this transom connection.
Exhaust temperature alarm display for engines with cooling water injection into the exhaust gas. Gives a visual and audible alarm if the temperature of the exhaust gas/water mixture in the exhaust hose becomes too high (over 75 °C). Otherwise, if there are problems with the engine cooling system, the hot exhaust gases from the engine can melt hoses, water collectors or silencers before the engine overheating alarm is triggered.Ideally, the indicator is installed in combination with the exhaust gas temperature sensor from VETUS, which is not included in the scope of delivery. The indicator is available in a 12 and 24 volt version and comes with two plastic covers, one black and one silver.
Gooseneck for exhaust hose. Raises the exhaust hose above the waterline so that water cannot backfill the exhaust system.
Combined gooseneck and silencer for exhaust systems with cooling water injection. The upper and lower sections can be rotated through 360 degrees, making installation and connection of the exhaust hoses much easier. The NLPG has significantly improved silencing and lower back pressure in the exhaust system than the WLOCKLT system, also from Vetus. The gooseneck prevents water from flowing back into the exhaust in rough seas and the silencer also creates water turbulence inside, which leads to a significant reduction in noise.Various hose connection diameters from 40 to 90 mm available. Installation At least 45 centimeters above the waterline (measured from the top of the NLPG) and as close as possible to the middle of the boat.
The sensor with bi-metal thermal switch is screwed into a small hole in the cooling water hose directly behind the exhaust manifold and warns of a lack of cooling water before the engine heats up too much. The sensor is wired to a free slot on the engine control panel or a separate VETUS alarm indicator (see accessories). At 71 °C, the sensor reacts and closes the circuit; a warning light and acoustic alarm are triggered on the panel or the external control. This allows the crew to switch off the engine before the exhaust gases, which are over 300 degrees hot, melt hoses, water collectors or silencers. Suitable for 12 and 24 V on-board power supplies.
Tried and tested waterlock for engine installations with water cooled exhaust systems.Robust PVC silencer in a double decker design of the type NLP.With standing, twistable muffler with twistable connectors for standing or hanging mounting in many installation situations.Good to very good noise absorption. With drainage nozzle.We have three of the most common designs on offer (see the Suitable Items further down below).Various additional designs are available upon request.
Tried and tested waterlock for engine installations with water cooled exhaust systems.Robust PVC silencer of the horizontal type NLPH with slim and twistable muffler with twistable connectors for many installation situations.Good to very good noise absorption. With drainage nozzle.We have three of the most common designs on offer (see the Suitable Items further down below). Various additional designs are available upon request.
Tried and tested waterlock for engine installations with water cooled exhaust systems.Robust PVC silencer in a z design of the type WLOCK for standing or hanging mounting, with twistable inlet for many installation situations.Good to very good noise absorption. With drainage nozzle.We have three of the most common designs on offer (see the Suitable Items further down below). Various additional designs are available upon request.
